
An advanced ECG simulator with 35 arrhythmia patterns, adjustable parameters, and square wave output for comprehensive cardiac training and equipment testing.
Model | VIT-E-500 |
Brand | Vitaliya Simulation Systems |
Category | Advanced Medical Simulators |
Training Type | ECG Monitoring, Arrhythmia Simulation & Biomedical Testing |
Application | Hospitals, Biomedical Departments, Medical Colleges, ECG Training Centers, Simulation Labs |
The Vitaliya ECG Simulator E-500 is an advanced and feature-rich device designed for comprehensive ECG training and biomedical equipment testing. With support for 35 different cardiac rhythms and arrhythmias, it offers an extensive platform for simulating both normal and complex heart conditions.
In addition to standard ECG waveform simulation, the device includes a square wave output function, making it highly effective for calibration and validation of ECG monitoring systems.
The simulator provides adjustable heart rate and amplitude settings, allowing users to replicate a wide range of clinical scenarios with high accuracy. Its compact design ensures easy portability, making it suitable for hospitals, training institutes, and biomedical engineering applications.
With its expanded functionality and precision, the ECG Simulator E-500 is an ideal solution for enhancing diagnostic skills, technical training, and equipment reliability testing.
Environment:
• 15°C to 40°C (59°F to 104°F)
• 10% to 90% Relative Humidity
• Indoor use only
Power Supply:
• 9V Alkaline Battery
• AC/DC Power Supply (9V–12V)
• Output Current: 500 mA
Dimensions & Weight:
• Size: 21.0 cm × 12.5 cm × 3.3 cm
• Weight: 0.45 kg
Amplitude (mV):
• 0.5 / 1.0 / 2.0
Amplitude Accuracy:
• ±2% (Lead II)
Heart Rate (BPM):
• 30, 45, 60, 90, 105, 120, 135, 150, 180
Rate Accuracy:
• ±1 BPM
Square Wave Output:
• 1 mV at 2 Hz
Supports a wide range of cardiac conditions including:
• Normal Sinus Rhythm
• Ventricular Tachycardia (VT1, VT2)
• Ventricular Fibrillation (Fine & Coarse)
• Asystole
• Junctional Tachycardia (JTACH)
• AV Nodal Rhythm
• Sinus Arrhythmia
• Premature Atrial Contractions (PAC)
• Premature Ventricular Contractions (PVC, R-on-T)
• Bigeminy & Trigeminy
• Atrial Fibrillation & Atrial Flutter
• Paroxysmal Atrial Tachycardia
• First, Second & Third Degree Heart Blocks
• Right & Left Bundle Branch Blocks (RBBB, LBBB)
• ST Segment Changes & Ischemia
• Wide QRS Complex
• Long QT Syndrome
• Idioventricular Rhythm
• Torsades de Pointes
• Sinus Bradycardia
• Square Wave Signal
• Accurate ECG waveform generation
• Suitable for monitor testing and calibration
• Stable and repeatable outputs
• Multiple BPM settings for varied clinical scenarios
• Adjustable amplitude levels
• Supports both normal and critical cardiac conditions
• Provides 1 mV / 2 Hz square wave
• Ideal for equipment calibration and validation
• Lightweight and portable
• Suitable for lab, classroom, and field use
• Built for long-term professional training
• Durable electronic casing
• High-quality internal circuitry
• ECG Simulator E-500 Unit
• Connection Leads
• Power Supply / Battery
• User Manual