A compact and reliable ECG simulator designed to generate multiple cardiac rhythms and arrhythmias for accurate diagnostic and training purposes.
Model | VIT-E-400 |
Brand | Vitaliya Simulation Systems |
Category | Advanced Medical Simulators |
Training Type | ECG Monitoring & Cardiac Rhythm Simulation |
Application | Hospitals, Biomedical Departments, Medical Colleges, ECG Training Centers, Simulation Labs |
The Vitaliya ECG Simulator E-400 is a versatile and high-precision device designed for ECG monitoring training and biomedical equipment testing. It enables users to simulate a wide range of cardiac rhythms and arrhythmias, making it an essential tool for clinical education and device validation.
With support for 15 different arrhythmias, including critical conditions such as ventricular fibrillation, atrial fibrillation, and AV blocks, the simulator provides a comprehensive learning experience for students and healthcare professionals.
The device offers adjustable heart rate and amplitude settings, allowing users to replicate different patient conditions accurately. Its compact and portable design makes it ideal for use in hospitals, biomedical departments, and training labs.
Built for reliability and ease of use, the ECG Simulator E-400 helps improve diagnostic accuracy, equipment testing efficiency, and clinical training outcomes.
Environment:
• 15°C to 40°C (59°F to 104°F)
• 10% to 90% Relative Humidity
• Indoor use only
Power Supply:
• 9V Alkaline Battery
• AC/DC Power Supply (9V–12V)
• Output Current: 500 mA
Dimensions & Weight:
• Size: 21.0 cm × 12.5 cm × 3.3 cm
• Weight: 0.45 kg
Amplitude (mV):
• 0.5 / 1.0 / 2.0
Amplitude Accuracy:
• ±2% (Lead II)
Heart Rate (BPM):
• 30, 45, 60, 90, 105, 120, 135, 150, 180
Rate Accuracy:
• ±1 BPM
Supports 15 different cardiac rhythms, including:
• Normal Sinus Rhythm
• Ventricular Tachycardia (V-Tach)
• Ventricular Fibrillation (VF)
• Atrial Fibrillation (AFIB)
• Atrial Flutter
• Sinus Bradycardia
• Sinus Tachycardia
• Sinus Arrest
• Sinus Exit Block
• Premature Atrial Contraction (PAC)
• Premature Ventricular Contraction (PVC)
• PVC R-on-T
• First Degree AV Block
• Third Degree AV Block (AV Block 3)
• Atrial Fibrillation with Block
• High precision ECG waveform generation
• Ensures reliable testing of ECG monitors and devices
• Stable and consistent signal performance
• Multiple heart rate (BPM) settings
• Adjustable signal amplitude levels
• Enables simulation of varied clinical conditions
• Lightweight and easy to carry
• Suitable for on-site testing and training
• Durable design for repeated use
• Durable electronic housing
• High-quality internal circuit components
• ECG Simulator E-400 Unit
• Connection Leads
• Power Supply / Battery
• User Manual